Editing Multiple Load Cases-

Use the Group Edit view of the Static Analysis – Load Case Editor to update values on multiple load cases at one time. This view saves you valuable time as you can make global changes to load cases, rather than having to edit each load case individually.

To perform a group edit of multiple load cases

1. Open a CAESAR II job.
2. Run error checking or the analysis, and then select Static Analysis.
3. Click Group Edit in the upper-right corner of the Static Analysis – Load Case Editor.

Static Analysis – Load Case Editor List View (the Default)

The List view shows all load cases in list format, making it easy to see a full view of load cases as you work.

Static Analysis – Load Case Editor Group Edit View 

The Group Edit view could be considered a bulk editor for all your load cases. This enables you to make mass changes to any selected load cases with just a few simple clicks.

To use the Group Edit view for changing load cases:

1.    Select multiple load cases and click Group Edit.

The software preserves the load case selections you made in the List view and keeps them highlighted in the Group Edit view.

2.    Change any field values in this view and the software updates all the load cases you previously selected.

3.    By toggling back to the List view, you can see the changes that were applied to each of the selected load cases.

Using the new Group Edit view can save a lot of time, and it only takes a few clicks.

Comments Off on Editing Multiple Load Cases-

Filed under CAESAR II, Home

Performing Fatigue Analysis on Nozzles in PV Elite

Performing fatigue analysis on nozzles using PV Elite is a simple process. Let us go through these steps to bring your fatigue information into PV Elite.

Once the Load Cases tab is active, click on the button that is next to ‘Fatigue Analysis’ and the Fatigue Pressure/Cycle Data Input screen appears. In the box at the top called ‘Number of Fatigue Case to Process,’ enter the number of cases you want considered. Then enter the pressure range and number of cycles for each range. Finally, click on the button at the bottom of the screen that says ‘Save Cases and Exit.’ At this point, PV Elite has all the information it needs to perform the fatigue analysis on any nozzles you add to your model.

Go back to the General Data Input tab where you find your model on the screen. When you add a nozzle to the vessel using the usual nozzle input screen, notice that at the bottom of screen the check box ‘Fatigue Calc ?’ Make sure this box is checked, see below:

Now, for the PD5500 and EN13445 models, the drop down list labeled ‘Weld Class’ beside the check box becomes active.  Choose a suitable letter (see PD 5500 Annex C for details concerning fatigue classes). Note, class C is the least severe, and W the most severe.  Enter the rest of your nozzle data, ensuring the nozzle is adequately reinforced in the normal way.

When you have finished entering your vessel data and have completed building your model, you can press the calculation button (running man). The output processor will include a fatigue analysis report. That report will contain the full analysis for all of the nozzles on which you indicated to perform fatigue analysis:


Comments Off on Performing Fatigue Analysis on Nozzles in PV Elite

Filed under PV Elite & Tank

SERVICE PACK 1 RELEASED FOR PV Elite 2017

PV Elite 2017 Service Pack 1 is released…

This is to notify you that PV Elite 2017 SP1 has been posted on Intergraph Smart Support website.

Download the same Service pack from Smart Support (https://smartsupport.intergraph.com//):

Select View Downloads > PV Elite.

Accept the legal notice and select Service Packs and Fixes.

From the PV Elite 2017 section, click to download PV Elite 2017 SP1 (19.00.01.0003).

This zip file contains several application executables, a library (DLL) and the hotfix readme with instructions.

PV Elite 2017 SP1 include all previously-released fixes to this version. To apply, download the attached zip file, unzip, and copy all files to the folders specified in the hotfix installation instructions found in the ReadMe file. For a review of what’s in this pack, see the ReadMe. To make sure the pack was applied, see the HELP menu found on PV Elite main window.

Note– Updates to the PV Elite product consist of Hot Fixes to fix one or more specific problems, or Service Packs which contain a significant number of fixes. These Hot Fixes and/or Service Packs are posted to this web page.

1. The Hot Fixes served on this page are issued through the PPM Product Center’s “quick fix” process. A quick checkout of the problems addressed has been executed, as well as limited regression testing, but the product has not gone through a full certification pass. Before downloading and installing a Hot Fix, we strongly recommend that you review the list of fixes in the Readme file, and install the Hot Fix only if the fixes will be of benefit to you. The Hot Fixes issued with these releases will be included in the next fully certified product release (Service Pack or Full Version.)

2. The Hot Fixes and Service Packs served on this page are zipped files, intended to be DOWNLOADED TO YOUR LOCAL SYSTEM ONLY; Please read all instructions, and make sure to use the SAVE TO LOCAL DISK option before clicking on any of the files on this page.

3. To get the login user name and password for smart support , Please send a login request email  to support@igfzco.com .

Comments Off on SERVICE PACK 1 RELEASED FOR PV Elite 2017

Filed under Home

Frequently Asked Question and Solution- How to recover PV- Elite corrupted file.

Query : PV-Elite file corrupted.

Issue :

.

Solution :

The issue resolved with Backup option. PV-Elite and CodeCalc to allow you to access a back-up copy of your PV-Elite and CodeCalc files by selecting Backup Folder on the File tab. The software saves a copy of your PV-Elite and CodeCalc jobs into the Backup folder in the program folder when you analyze the job.


Comments Off on Frequently Asked Question and Solution- How to recover PV- Elite corrupted file.

Filed under Home

CAESAR II-2016 Hotfix 4 is released…

This is to notify you that CAESAR-II 2016 hotfix 4 has been posted on Intergraph Smart Support website.

 

Download the hotfix from Smart Support (https://smartsupport.intergraph.com//):

  1. Select View Downloads > CAESAR II.

  2. Accept the legal notice and select Service Packs and Fixes.

  3. From the CAESAR II 2016 section, click to download CAESAR II 2016 (08.00.00.5604).
    This zip file contains several application executables, a library (DLL) and the hotfix readme with instructions.


CAESAR II- 2016 hotfixes 4 include all previously-released fixes to this version.  To apply, download the attached zip file, unzip, and copy all files to the folders specified in the hotfix installation instructions found in the ReadMe file.  For a review of what’s in this pack, see the ReadMe.  To make sure the pack was applied, see the Build.txt file found on the Help tab in the CAESAR II main window.


Note- Before downloading and installing a Hot Fix, we strongly recommend that you review the list of fixes in the Readme file, and install the Hot Fix only if the fixes will be of benefit to you. The Hot Fixes issued with these releases will be included in the next fully certified product release (Service Pack or Full Version.)

Comments Off on CAESAR II-2016 Hotfix 4 is released…

Filed under Home

How to get Separate Report for Foundation Loads from PV Elite Software

This is the new feature of PV Elite 2016 by adding an option to separate the foundation load information. Previously, the software only displayed basering and foundation load information on the Vessel Design Summary report. You can now select Foundation Loads on a New Page on the Configuration dialog which will result in the basering and foundation load information displaying on the new Foundation Support Summary report. A new Basering Cross Section View sketch also displays on both the Vessel Design Summary report and Foundation Support Summary report.

 

You will find a separate report for Foundation Loads:

 

1 Comment

Filed under Home

Intergraph PV-Elite 2015 SP2 hasbeen released.

Dear Customer,

Intergraph PV-Elite 2015 SP2 has been released.

Here is the website to download the service pack,

https://smartsupport.intergraph.com/

In order to  download this service pack, you need the user name and password to login above Intergraph Smart Support . If you do not have user name and password, Kindly send the email to